Contact
ABRG Asamer-Becker Recycling GmbH
Industriestraße 17
A 9601 Arnoldstein
- +43 4255 3990 – 89
Emissions Data
Emmisions Data for the Fluidised Bed Furnace 1 (WSO I)
Parameter | Unit | Limit Value HHA | Curr. Value |
---|---|---|---|
CO
|
mg/Nm³
|
100
|
5,28
|
SO2
|
mg/Nm³
|
50
|
23,61
|
NOx
|
mg/Nm³
|
200
|
122,81
|
GesCorg
|
mg/Nm³
|
10
|
0,81
|
Dust
|
mg/Nm³
|
10
|
3,74
|
NH3
|
mg/Nm³
|
5
|
1,59
|
Updated at: 25.04.2024 - 10:00
Data: www.eudt.at
Emmisions Data for the Fluidised Bed Furnace 2 (WSO II)
Parameter | Unit | Limit Value HHA | Curr. Value |
---|---|---|---|
CO
|
mg/Nm³
|
100
|
18,55
|
SO2
|
mg/Nm³
|
50
|
28,31
|
NOx
|
mg/Nm³
|
200
|
138,63
|
GesCorg
|
mg/Nm³
|
10
|
1,8
|
Dust
|
mg/Nm³
|
10
|
0,29
|
NH3
|
mg/Nm³
|
5
|
1,38
|
Updated at: 25.04.2024 - 10:00
Data: www.eudt.at